Gamma Vacuum
Creating the purest vacuum environments on Earth
MENU

Ion Pump Controllers

MPCQ

MPCQ

Ordering PN:

Description:

Price:


Bookmark and Share

HV Channels

Configurable for 1 to 4 output connectors.  Multiple Ion pumps running on one high voltage supply operate in parallel.

Configurable for 1 to 4 output connectors. Multiple Ion pumps running on one high voltage supply operate in parallel.

HV Channels

Configured with two outputs per HV channel.  Multiple Ion pumps running on one high voltage supply operate in parallel.

Configured with two outputs per HV channel. Multiple Ion pumps running on one high voltage supply operate in parallel.

HV Polarity

Postive polarity is applied to Diode style pumping elements

Postive polarity is applied to Diode style pumping elements

HV Polarity

Negative polarity is applied to Triode syle pumping elements

Negative polarity is applied to Triode syle pumping elements

Connector Style

The 10 kV SHV output is standard  for current and historical controllers

The 10 kV SHV output is standard for current and historical controllers

Connector Style

Available Fischer with Interlock for existing Varian/Agilent pump installations

Available Fischer with Interlock for existing Varian/Agilent pump installations

Connections/Channel

One Output per Channel (10kV SHV shown)

One Output per Channel (10kV SHV shown)

Connections/Channel

Two Outputs per Channel  (10kV SHV shown)

Two Outputs per Channel (10kV SHV shown)

Connections/Channel

Single Channel with Three Outputs (10kV SHV shown)

Single Channel with Three Outputs (10kV SHV shown)

Connections/Channel

Single Channel with Four Outputs (10kV SHV shown)

Single Channel with Four Outputs (10kV SHV shown)

Input Voltage

110-volt, US Connector

110-volt, US Connector

Input Voltage

220-volt, US Connector

220-volt, US Connector

Input Voltage

230-volt, European Connector

230-volt, European Connector

Input Voltage

230-volt, United Kingdom Connector

230-volt, United Kingdom Connector

Input Voltage

230-volt, Australian Connector

230-volt, Australian Connector

Input Voltage

Bare wire for 24v battery or rack power supply.

Bare wire for 24v battery or rack power supply.

Communications

Serial/Ethernet configurable

Serial/Ethernet configurable

Communications

Profibus/Serial/Ethernet configurable

Profibus/Serial/Ethernet configurable

Remote Enable

High voltage can be controlled by alternate controller set-points

High voltage can be controlled by alternate controller set-points

TSP/NEG Control

Select TSP/NEG control to add TSP/NEG control harware.

Select TSP/NEG control to add TSP/NEG control harware.

TSP/NEG Control

Interface with a remote TSP/NEG controller over long distances.

Interface with a remote TSP/NEG controller over long distances.

TSP/NEG Control

Interface with a dual remote TSP/NEG controller over long distances.

Interface with a dual remote TSP/NEG controller over long distances.

TSP/NEG Control

Interface with a remote TSP/NEG controller over long distances.

Interface with a remote TSP/NEG controller over long distances.

TSP/NEG Control

Interface with a remote TSP/NEG controller over long distances.

Interface with a remote TSP/NEG controller over long distances.

TSP/NEG Control

Control a TSP from the MPC

Control a TSP from the MPC

TSP/NEG Control

Control a NEG from the MPC

Control a NEG from the MPC

Unit Options

HV Channels



HV Polarity




Connector Style



Connections/Channel






Input Voltage







Communications




Remote Enable


TSP/NEG Control








Specifications

Weight: 16.8 (37) min., 25.4 (56) max. kg (lbs)
Shipping Weight: 32 (66) kg (lbs)
Dimensions: 483 x 133 x 476 mm, l x w x d
Input Power: 120-220/48-62 volts/Hz
Output: +7000 (CV/DI), -5600 (TR) volts
Output: 500 current (mA)
Power: 1000 maximum Watts
Resolution: 0.1 uA
Output Connectors: 1-4 10kV SHV or Fischer
Display Type: 1/4 VGA LCD w/touchscreen
Analog Voltage Ouput: 1V per 1000V
Analog Current/Pressure Output: user configurable
Set Points: 4 TTL, 4 Relay
Humidity: 0 to 80% RH, noncondensing
Temperature: 0 to 40 deg C
Communications: RS232, RS422, RS485, Ethernet
Conformity to Norms: EN61000-6-1, EN61000-4-2, EN61000-4-3, EN61000-4-4, EN 61010-1

Downloads

Login Required (click here)

  • MPCq Specification Sheet
  • MPCq Firmware Update (1.28)
  • DIGITEL MPCq Manual (pdf)
  • DIGITEL MPCq Line Drawing (pdf)
  • DIGITEL LabVIEW Serial Driver
  • DIGITEL Brochure