Gamma Vacuum
Creating the purest vacuum environments on Earth
MENU

Low Profile Ion Pumps

600LX

600LX

Ordering PN:

Description:

Price:


Bookmark and Share

Element Style

Conventional elements  (100% Ti) are for standard air and non-noble gas loads.

Conventional elements (100% Ti) are for standard air and non-noble gas loads.

Element Style

Differential elements (50% Ti/50%Ta) are stable for noble gas loads.

Differential elements (50% Ti/50%Ta) are stable for noble gas loads.

Element Style

Conventional elements  (100% Ti) are for standard air and non-noble gas loads.  Zero emmissions shielding and XHV operation.

Conventional elements (100% Ti) are for standard air and non-noble gas loads. Zero emmissions shielding and XHV operation.

Element Style

Differential elements (50% Ti/50%Ta) are stable for noble gas loads. Zero emmissions shielding and XHV operation.

Differential elements (50% Ti/50%Ta) are stable for noble gas loads. Zero emmissions shielding and XHV operation.

Element Style

Triode elements use slotted titanium cathodes and are stable for noble gas loads.

Triode elements use slotted titanium cathodes and are stable for noble gas loads.

Port Options

8 CFF, Single (DN 150) Inlet Port

8 CFF, Single (DN 150) Inlet Port

Port Options

8 CFF, Double (DN 150),   Second port accepts NEG/TSP

8 CFF, Double (DN 150), Second port accepts NEG/TSP

Port Options

8 CFF, Single (DN 150) and 8 CFF, Sideport (DN 150). Second port accepts NEG/TSP.

8 CFF, Single (DN 150) and 8 CFF, Sideport (DN 150). Second port accepts NEG/TSP.

Port Options

10 CFF, Single (DN 200) Inlet Port

10 CFF, Single (DN 200) Inlet Port

Port Options

10 CFF (DN 200), Second 8 CFF port accepts NEG/TSP

10 CFF (DN 200), Second 8 CFF port accepts NEG/TSP

Port Options

10 CFF, Single (DN200), Second 8 CFF sideport for NEG/TSP

10 CFF, Single (DN200), Second 8 CFF sideport for NEG/TSP

HV Feedthrough

SAFECONN 10kv SHV Feedthrough  (Standard)

SAFECONN 10kv SHV Feedthrough (Standard)

HV Feedthrough

Original Perkin Elmer Feedthrough (1980-1995)

Original Perkin Elmer Feedthrough (1980-1995)

HV Feedthrough

Original Varian Feedthrough

Original Varian Feedthrough

HV Feedthrough

Varian Starcell Feedthrough

Varian Starcell Feedthrough

HV Feedthrough

Varian Compatible Fischer with Interlock

Varian Compatible Fischer with Interlock

Heater Voltage

Select heater voltage and connector style if baking is required.

Select heater voltage and connector style if baking is required.

Heater Voltage

90-120 volt input

90-120 volt input

Heater Voltage

208-240 volt input

208-240 volt input

TSP/NEG

Select a TSP/NEG option with a double 8 CFF (DN 150) or 6 CFF (DN 100) port

Select a TSP/NEG option with a double 8 CFF (DN 150) or 6 CFF (DN 100) port

TSP/NEG

2.75 CFF TSP and Cryoshroud installed in second port

2.75 CFF TSP and Cryoshroud installed in second port

TSP/NEG

2.75 CFF TSP and Ambient Sheild installed in second port

2.75 CFF TSP and Ambient Sheild installed in second port

TSP/NEG

N400 installed in second port for increased hydrogen pumping at UHV

N400 installed in second port for increased hydrogen pumping at UHV

Options

Element Style






Port Options








HV Feedthrough






Heater Voltage





TSP/NEG





Specifications

Weight: 122 (270) kg (lbs)
Shipping Weight: 141 (310) kg (lbs)
Ultimate Pressure: less than 10-11 mbar
Starting Pressure: 1 x 10-3 mbar
Lifetime: 50,000 hours @ e-6 mbar
Operating Bake Temp: 250 Deg C
Maximum Bake Temp: 450 without magnets Deg C
Dimensions: 537 x 413 x 336 mm, l x w x d

Downloads

Login Required (click here)

  • Ion Pump NRTL Certification
  • Ion Pump Manual (pdf)
  • Ion Pump CE Declaration of Conformity
  • Ion Pump Brochure
  • 600LX Specification Sheet
  • 600LX Magnetic Field Plot (pdf)
  • 600LX Line Drawings (pdf)
  • 600LX CAD Files (zip)